保護對象:
T1電(dian)(dian)(dian)(dian)(dian)涌保護(hu)器(qi)主要(yao)安裝(zhuang)在建筑物總進線柜及(ji)室外(wai)電(dian)(dian)(dian)(dian)(dian)氣柜,適用于交流(liu)供配(pei)電(dian)(dian)(dian)(dian)(dian)系統220V/380V(50Hz/60Hz)TN-S、TN-C-S、TT、IT等供電(dian)(dian)(dian)(dian)(dian)系統的(de)雷(lei)(lei)擊電(dian)(dian)(dian)(dian)(dian)磁脈沖保護(hu)(LEMP)。應用于雷(lei)(lei)擊風(feng)險較高地區(qu)的(de)設(she)備(bei)系統的(de)電(dian)(dian)(dian)(dian)(dian)源第一級(ji)電(dian)(dian)(dian)(dian)(dian)涌保護(hu)。其(qi)設(she)計依據符合(he)GB18802.1,IEC61643-1技術(shu)標(biao)準,屬于防(fang)雷(lei)(lei)等級(ji)的(de)T1級(ji)防(fang)雷(lei)(lei)產品(pin),10/350μs沖擊放電(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)流(liu)為50kA,8/20μs標(biao)稱放電(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)流(liu)為100kA。適用于60V~550V系統的(de)雷(lei)(lei)電(dian)(dian)(dian)(dian)(dian)過電(dian)(dian)(dian)(dian)(dian)壓防(fang)護(hu)。
技術參數:
Un額定電(dian)壓 |
380V |
Uc最(zui)大持續工作電壓 |
420V |
Up電壓(ya)保護水平(ping) |
≤1.5kV |
In標(biao)稱放電電流(8/20μs) |
80kA(8/20μs) |
Imax最大放電電流(liu)(10/350μs) |
150kA(8/20μs) |
泄露電流(liu) |
≤20μA |
響應時間 |
≤25ns |
保護模(mo)式 |
L1、L2、L3-PE |
執行標準:
IEC 61643-11:2011 低壓電涌保護器(SPD)第11部分:低壓電力系統的電涌保護器性能要求和試驗方法 EN 61643-11:2012 低壓(ya)電(dian)涌(yong)保護器(SPD)第11部分:低壓(ya)電(dian)力系統的(de)電(dian)涌(yong)保護器性能要求和試驗方(fang)法
|